Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor

Overview 12.1 inch Multi-parameter Patient MonitorModel: MCS0183 Features 1. 12.1" color TFT LCD screen, resolution: 800
Basic Info
Model NO. MCS0183
Measurement Range Adult: 10~ 120 Brpm
Neonatal I Pediatric 7 ~ 150 Brpm
Resolution 1 Brpm
Accuracy +2 Brpm
Measure and Alarm Range 0 ~ 50 C
Specification standard size
Trademark MeCan
Origin China
Production Capacity 1000 PCS/Month
Product Description

12.1 inch Multi-parameter Patient MonitorModel: MCS0183

Features

1. 12.1" color TFT LCD screen, resolution: 800*600 2. 5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG3. Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)4. 96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events5. ST and arrhythmia analysis, pacemaker analysis, drug dose calculation6. Anti‐defibrillation design 7. NIBP over pressure protection8. Plug‐in rechargeable battery, AC/DC available9. Support wire or wireless network

Product Description

Technique Specification

SPO2TEMP
Measuring Range: 0 ~ 100 %Measure and Alarm Range: 0~ 50 C
Resolution: 1%Resolution: 0.1C
Accuracy: 70% ~ 100% (+2 %)Accuracy: +0.1C
Pulse Rate: 20-250 BPM
Resolution: 1 BPMRESP
Accuracy: +3 BPMMethod: Impedance between RA-LLor RAL A
Measurement Range:
NIBPAdult: 10 ~ 120 BrPM
Method: OscillometryNeonatal I Pediatric: 7 ~ 150 BrPM
Measure mode: Manual, Auto, STATResolution: 1 BrPM
Unit: mmHg, kPaAccuracy: +2 BrPM
Measure and alarm range:
Adult ModeECG
SYS 40 ~ 280 mmHgLead Mode: 5 Leads (I, II, I,, AVR, AVL ,AVF, V)
DIA:10 ~ 225 mmHgGain: 2 5mm/mV, 5. 0mm/mV, 10mm/mV, 20mm/mV
MEAN 20 ~ 240 mmHgHeart Rate: 15 300 BPM (Adult); 15 350 BPM (Neonatal)
Pediatric ModeResolution: 1 BPM
SYS 40 ~ 220 mmHgAccuracy: +1%
DIA 10 ~ 160 mmHgSensitivity >200 uV(Peak to peak)
MEAN 20 ~ 170 mmHgST measurement range: -2.0 ~ +2.0 mV
Neonatal ModeAccuracy: -0 8mV~+0.8mV: +0.02mV or +10%,which is greater
SYS 40 ~ 135 mmHgOther Range: unspecified
DIA 10 ~ 100 mmHgSweep speed: 12.5 mm/s, 25mm/s, 50mm/s
MEAN 20 ~ 110 mmHg
Resolution: 1mmHg
Accuracy: +5mmHg

Standard Parameters:ECG, RESP, TEMP, NIBP, SPO2, PR

Optinal Parameters:Recorder ( Printer)Central monitoring systemDual IBPEtco212-lead ECG;Nellco SpO2;Sun Tech NIBP.Product Application:

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor


Packaging & Shipping
Standard Accessories
NO.ItemQty
1Main Unit1
25-lead ECG cable1
3Disposable ECG Electrode5
4Adult Spo2 probe1
5Adult NIBP cuff1
6NIBP extension tube1
7Temperature probe1
8Power Cable1
9User Manual1
10Fuse3

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor

More Product

Company Profile

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor

Factory Cardiac NIBP Monitoring System with Etco2 12 Inches Patient China Multi-Parameter Monitor